Project

General

Profile

Activity

From 11/14/2016 to 12/13/2016

12/02/2016

07:53 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
Anton,
The dark calibration would have been cleared when you reflashed the SD card. For best performance, you shou...
Jeffrey Myers
05:19 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
Update. It return non zero images only for exposures bigger than 6 sec.
With exposures in interval 6.01 - 6.1 sec im...
Anton Bakulev
03:07 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
Jeffrey,
Thank you for your reply. I've upgraded a firmware successfully. Now it reports the following:...
Anton Bakulev
03:01 AM Support: RE: There is no eth0 device in 40-000065-4 release firmware
Jeffrey,
Thank you. Yes, this instructions fixes the problem. Now my MityCam works well by eth0.
Anton Bakulev

12/01/2016

07:56 AM Support: RE: There is no eth0 device in 40-000065-4 release firmware
Anton,
I sent you an email with instructions on reconfiguring the camera.
Jeffrey Myers
04:44 AM Support: There is no eth0 device in 40-000065-4 release firmware
Hello,
I've installed a 40-000065-4 release firmware from [[https://support.criticallink.com/redmine/projects/mity...
Anton Bakulev

11/29/2016

07:40 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
Thank you.
Yes, it's fully enclosed camera that was re-flashed several months ago in this post? [[https://support.cr...
Anton Bakulev
07:29 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
Anton Bakulev wrote:
> I've tried to set clock rate to 40MHz but images acquired after that is zero valued. Did you ...
Jeffrey Myers
05:42 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
I've tried to set clock rate to 40MHz but images acquired after that is zero valued. Did you tried this approach on y... Anton Bakulev

11/28/2016

11:05 AM Support: RE: Gain regulation for high and low gain channels in MityCam-CIS1910
We currently do not support altering the gain settings in the camera. For rolling they are fixed to x1 / x30 in comb... Michael Williamson
10:53 AM Support: Gain regulation for high and low gain channels in MityCam-CIS1910
There is an ability to switch low gain channel from x1 to x3 and high gain from x10 to x30 in CIS1910 sensor. Could y... Anton Bakulev
10:31 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
Anton Bakulev wrote:
> Could you write also is it possible to change clock speed by MityViewer app?
Unfortunately...
Jeffrey Myers
08:55 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
Also could you write a full structure definition tsCisParamSCLKRate ?
I could not find it in https://support.critica...
Anton Bakulev
08:48 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
Thank you for an explanation and a part of code.
Could you write also is it possible to change clock speed by MityV...
Anton Bakulev
07:50 AM Support: RE: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
When using the clcamiface API or MityViewer, you need to set the frame interval to something greater than the desired... Jeffrey Myers
02:56 AM Support: Acquiring images from MityCam CIS1910 with exposures grater than 1 sec
I'm trying to acquire images from MityCam CIS1910 by using clcamiface API or by using MityViewer and I don't see a di... Anton Bakulev
09:18 AM Support: RE: Maximum values for HighGain, LowGain and Combined modes for MityCAM-CIS1910
I do not see a specification for the ADC converters to be 12 bit, only 11 bit. Can you please provide me a reference... Michael Williamson
08:44 AM Support: Maximum values for HighGain, LowGain and Combined modes for MityCAM-CIS1910
I tested maximum values in images acquired from MityCAM-CIS1910 and got that
for HighGain and LowGain there is 2047...
Anton Bakulev
 

Also available in: Atom

Go to top
Add picture from clipboard (Maximum size: 1 GB)