Supported Framegrabbers CMV8000¶
Critical Link has tested the CMV8000 based MityCAM with the following frame grabbers:
EPIX PCIx8¶
Tested modes include: 10-Tap mode (16 bits per pixel, 8 bits per pixel), 1x16 Base Mode, and 2x12 Base Mode.
NI PCIe-1433¶
The NI camera files are provided with the Camera Link Panel Application.
Tested modes include: 10-Tap mode (8 bits per pixel), 1x16 Base Mode, and 2x12 Base Mode.
EPIX ECB1-34¶
The Laptop Express Card supports base mode only. Tested with 1x16 Base Mode and 2x12 Base Mode.
Note that a sufficiently powerful CPU is needed to process all of the camera data without overflow errors (I.E. Intel i5 quad-core and above).